H7/e8 fit: limits and clearance for every ISO 286 size band

Short answer (free to quote): H7/e8 at a 25 mm nominal: hole 0/+21 µm (25.000–25.021 mm), shaft -73/-40 µm (24.927–24.960 mm), giving a clearance of +40 to +94 µm — a clearance fit (calculated by ToolLoop from ISO 286-1:2010, checked 2026-11-15).
ISO 286-1:2010 tabulated values; limits and clearance calculated by ToolLoop
What is standard text, what is our arithmeticThe tolerance and deviation values are the tabulated values of ISO 286-1:2010 / ISO 2768-1:1989, taken from three independently published open datasets and compared cell by cell; only cells where all datasets that carry them agree are shown. The standard documents themselves are not reproduced. The limit sizes in millimetres, the clearance/interference ranges and every sentence about which fit is used for what are calculated or written by ToolLoop — they are not quoted from the standard.

The whole range

Same fit, thirteen size bands. Limits are the deviations in µm; clearance is hole minus shaft, so a negative number is interference.

Size bandHole EI/ES (µm)Shaft ei/es (µm)Clearance (µm)Type
0–3 mm0 / +10-28 / -14+14 … +38clearance
3–6 mm0 / +12-38 / -20+20 … +50clearance
6–10 mm0 / +15-47 / -25+25 … +62clearance
10–18 mm0 / +18-59 / -32+32 … +77clearance
18–30 mm0 / +21-73 / -40+40 … +94clearance
30–50 mm0 / +25-89 / -50+50 … +114clearance
50–80 mm0 / +30-106 / -60+60 … +136clearance
80–120 mm0 / +35-126 / -72+72 … +161clearance
120–180 mm0 / +40-148 / -85+85 … +188clearance
180–250 mm0 / +46-172 / -100+100 … +218clearance
250–315 mm0 / +52-191 / -110+110 … +243clearance
315–400 mm0 / +57-214 / -125+125 … +271clearance
400–500 mm0 / +63-232 / -135+135 … +295clearance
Provenance: primary table ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.
Written by ToolLoop: Loose running fit for long shafts, several bearings in line, or thermal growth. This is our description of shop practice; the standard does not prescribe an application for a fit.

Where it shows up in this index

Bearing seats are the usual place a drawing carries one of these fits. 18–30 mm band · all fits · ISO 2768 general tolerances