ISO 286 limits and fits: IT grades, H7/h6, h6 and the clearance they produce

Short answer (free to quote): ISO 286 writes a tolerance as a letter plus a grade. The letter fixes where the zone sits; the grade fixes its width. At a nominal 25 mm, H7 is 0 to +21 µm and h6 is 0 to −13 µm, so the pair H7/h6 gives a clearance between 0 and 34 µm (calculated by ToolLoop from the ISO 286-1:2010 tables, checked 2026-11-15).
ISO 286-1:2010 tabulated values; limits calculated by ToolLoop
What is standard text, what is our arithmeticThe tolerance and deviation values are the tabulated values of ISO 286-1:2010 / ISO 2768-1:1989, taken from three independently published open datasets and compared cell by cell; only cells where all datasets that carry them agree are shown. The standard documents themselves are not reproduced. The limit sizes in millimetres, the clearance/interference ranges and every sentence about which fit is used for what are calculated or written by ToolLoop — they are not quoted from the standard.

Standard tolerance grades IT5–IT11, µm

The grade width is the number after the letter. Read the row for the size band the nominal dimension falls in — the bands are "over … up to and including", so 25 mm sits in 18–30, not 10–18.

Over–up toIT5IT6IT7IT8IT9IT10IT11
0–3 mm461014254060
3–6 mm581218304875
6–10 mm691522365890
10–18 mm81118274370110
18–30 mm91321335284130
30–50 mm1116253962100160
50–80 mm1319304674120190
80–120 mm1522355487140220
120–180 mm18254063100160250
180–250 mm20294672115185290
250–315 mm23325281130210320
315–400 mm25365789140230360
400–500 mm27406397155250400
Provenance: primary table ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.

Common hole-basis fits at 25 mm

Sixteen fits, each with the limits of its parts and the resulting clearance at a 25 mm nominal. Negative clearance is interference.

FitTypical useHole EI/ES (µm)Shaft ei/es (µm)Clearance range (µm)
H7/h6location, no play0 / +21-13 / 00 … +34
H7/g6sliding, close0 / +21-20 / -7+7 … +41
H7/f7running, lubricated0 / +21-41 / -20+20 … +62
H7/e8easy running0 / +21-73 / -40+40 … +94
H7/d9loose running0 / +21-117 / -65+65 … +138
H7/js6transition, symmetric0 / +21-6.5 / +6.5-6.5 … +27.5
H7/k6transition, light tap0 / +21+2 / +15-15 … +19
H7/m6transition, light press0 / +21+8 / +21-21 … +13
H7/n6transition, press0 / +21+15 / +28-28 … +6
H7/p6interference, press0 / +21+22 / +35-35 … -1
H7/r6interference, shrink0 / +21+28 / +41-41 … -7
H7/s6interference, shrink0 / +21+35 / +48-48 … -14
H8/f7running, general0 / +33-41 / -20+20 … +74
H8/h7sliding, loose location0 / +33-21 / 00 … +54
H9/d9loose, unlocated0 / +52-117 / -65+65 … +169
H11/c11very loose0 / +130-240 / -110+110 … +370
Written by ToolLoop: the "typical use" column and every clearance range here are our summary of standard shop practice, not text from the standard.