H7/h6 fit: limits and clearance for every ISO 286 size band

Short answer (free to quote): H7/h6 at a 25 mm nominal: hole 0/+21 µm (25.000–25.021 mm), shaft -13/0 µm (24.987–25.000 mm), giving a clearance of 0 to +34 µm — a clearance fit (calculated by ToolLoop from ISO 286-1:2010, checked 2026-11-15).
ISO 286-1:2010 tabulated values; limits and clearance calculated by ToolLoop
What is standard text, what is our arithmeticThe tolerance and deviation values are the tabulated values of ISO 286-1:2010 / ISO 2768-1:1989, taken from three independently published open datasets and compared cell by cell; only cells where all datasets that carry them agree are shown. The standard documents themselves are not reproduced. The limit sizes in millimetres, the clearance/interference ranges and every sentence about which fit is used for what are calculated or written by ToolLoop — they are not quoted from the standard.

The whole range

Same fit, thirteen size bands. Limits are the deviations in µm; clearance is hole minus shaft, so a negative number is interference.

Size bandHole EI/ES (µm)Shaft ei/es (µm)Clearance (µm)Type
0–3 mm0 / +10-6 / 00 … +16clearance
3–6 mm0 / +12-8 / 00 … +20clearance
6–10 mm0 / +15-9 / 00 … +24clearance
10–18 mm0 / +18-11 / 00 … +29clearance
18–30 mm0 / +21-13 / 00 … +34clearance
30–50 mm0 / +25-16 / 00 … +41clearance
50–80 mm0 / +30-19 / 00 … +49clearance
80–120 mm0 / +35-22 / 00 … +57clearance
120–180 mm0 / +40-25 / 00 … +65clearance
180–250 mm0 / +46-29 / 00 … +75clearance
250–315 mm0 / +52-32 / 00 … +84clearance
315–400 mm0 / +57-36 / 00 … +93clearance
400–500 mm0 / +63-40 / 00 … +103clearance
Provenance: primary table ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.
Written by ToolLoop: Locating parts that are dismantled often: the hole and shaft nominally coincide and the pair can be assembled by hand. This is our description of shop practice; the standard does not prescribe an application for a fit.

Where it shows up in this index

Bearing seats are the usual place a drawing carries one of these fits. 18–30 mm band · all fits · ISO 2768 general tolerances