H7/k6 fit: limits and clearance for every ISO 286 size band

Short answer (free to quote): H7/k6 at a 25 mm nominal: hole 0/+21 µm (25.000–25.021 mm), shaft +2/+15 µm (25.002–25.015 mm), giving a clearance of -15 to +19 µm — a transition fit (calculated by ToolLoop from ISO 286-1:2010, checked 2026-11-15).
ISO 286-1:2010 tabulated values; limits and clearance calculated by ToolLoop
What is standard text, what is our arithmeticThe tolerance and deviation values are the tabulated values of ISO 286-1:2010 / ISO 2768-1:1989, taken from three independently published open datasets and compared cell by cell; only cells where all datasets that carry them agree are shown. The standard documents themselves are not reproduced. The limit sizes in millimetres, the clearance/interference ranges and every sentence about which fit is used for what are calculated or written by ToolLoop — they are not quoted from the standard.

The whole range

Same fit, thirteen size bands. Limits are the deviations in µm; clearance is hole minus shaft, so a negative number is interference.

Size bandHole EI/ES (µm)Shaft ei/es (µm)Clearance (µm)Type
0–3 mm0 / +100 / +6-6 … +10transition
3–6 mm0 / +12+1 / +9-9 … +11transition
6–10 mm0 / +15+1 / +10-10 … +14transition
10–18 mm0 / +18+1 / +12-12 … +17transition
18–30 mm0 / +21+2 / +15-15 … +19transition
30–50 mm0 / +25+2 / +18-18 … +23transition
50–80 mm0 / +30+2 / +21-21 … +28transition
80–120 mm0 / +35+3 / +25-25 … +32transition
120–180 mm0 / +40+3 / +28-28 … +37transition
180–250 mm0 / +46+4 / +33-33 … +42transition
250–315 mm0 / +52+4 / +36-36 … +48transition
315–400 mm0 / +57+4 / +40-40 … +53transition
400–500 mm0 / +63+5 / +45-45 … +58transition
Provenance: primary table ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.
Written by ToolLoop: A light interference in most sizes: the part is tapped home and stays put. This is our description of shop practice; the standard does not prescribe an application for a fit.

Where it shows up in this index

Bearing seats are the usual place a drawing carries one of these fits. 18–30 mm band · all fits · ISO 2768 general tolerances