H7/k6 at a 25 mm nominal: hole 0/+21 µm (25.000–25.021 mm), shaft +2/+15 µm (25.002–25.015 mm), giving a clearance of -15 to +19 µm — a transition fit (calculated by ToolLoop from ISO 286-1:2010, checked 2026-11-15).Same fit, thirteen size bands. Limits are the deviations in µm; clearance is hole minus shaft, so a negative number is interference.
| Size band | Hole EI/ES (µm) | Shaft ei/es (µm) | Clearance (µm) | Type |
|---|---|---|---|---|
| 0–3 mm | 0 / +10 | 0 / +6 | -6 … +10 | transition |
| 3–6 mm | 0 / +12 | +1 / +9 | -9 … +11 | transition |
| 6–10 mm | 0 / +15 | +1 / +10 | -10 … +14 | transition |
| 10–18 mm | 0 / +18 | +1 / +12 | -12 … +17 | transition |
| 18–30 mm | 0 / +21 | +2 / +15 | -15 … +19 | transition |
| 30–50 mm | 0 / +25 | +2 / +18 | -18 … +23 | transition |
| 50–80 mm | 0 / +30 | +2 / +21 | -21 … +28 | transition |
| 80–120 mm | 0 / +35 | +3 / +25 | -25 … +32 | transition |
| 120–180 mm | 0 / +40 | +3 / +28 | -28 … +37 | transition |
| 180–250 mm | 0 / +46 | +4 / +33 | -33 … +42 | transition |
| 250–315 mm | 0 / +52 | +4 / +36 | -36 … +48 | transition |
| 315–400 mm | 0 / +57 | +4 / +40 | -40 … +53 | transition |
| 400–500 mm | 0 / +63 | +5 / +45 | -45 … +58 | transition |
ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.Bearing seats are the usual place a drawing carries one of these fits. 18–30 mm band · all fits · ISO 2768 general tolerances