H7/m6 fit: limits and clearance for every ISO 286 size band

Short answer (free to quote): H7/m6 at a 25 mm nominal: hole 0/+21 µm (25.000–25.021 mm), shaft +8/+21 µm (25.008–25.021 mm), giving a clearance of -21 to +13 µm — a transition fit (calculated by ToolLoop from ISO 286-1:2010, checked 2026-11-15).
ISO 286-1:2010 tabulated values; limits and clearance calculated by ToolLoop
What is standard text, what is our arithmeticThe tolerance and deviation values are the tabulated values of ISO 286-1:2010 / ISO 2768-1:1989, taken from three independently published open datasets and compared cell by cell; only cells where all datasets that carry them agree are shown. The standard documents themselves are not reproduced. The limit sizes in millimetres, the clearance/interference ranges and every sentence about which fit is used for what are calculated or written by ToolLoop — they are not quoted from the standard.

The whole range

Same fit, thirteen size bands. Limits are the deviations in µm; clearance is hole minus shaft, so a negative number is interference.

Size bandHole EI/ES (µm)Shaft ei/es (µm)Clearance (µm)Type
0–3 mm0 / +10+2 / +8-8 … +8transition
3–6 mm0 / +12+4 / +12-12 … +8transition
6–10 mm0 / +15+6 / +15-15 … +9transition
10–18 mm0 / +18+7 / +18-18 … +11transition
18–30 mm0 / +21+8 / +21-21 … +13transition
30–50 mm0 / +25+9 / +25-25 … +16transition
50–80 mm0 / +30+11 / +30-30 … +19transition
80–120 mm0 / +35+13 / +35-35 … +22transition
120–180 mm0 / +40+15 / +40-40 … +25transition
180–250 mm0 / +46+17 / +46-46 … +29transition
250–315 mm0 / +52+20 / +52-52 … +32transition
315–400 mm0 / +57+21 / +57-57 … +36transition
400–500 mm0 / +63+23 / +63-63 … +40transition
Provenance: primary table ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.
Written by ToolLoop: Slightly tighter than k6; assembled with a light press. This is our description of shop practice; the standard does not prescribe an application for a fit.

Where it shows up in this index

Bearing seats are the usual place a drawing carries one of these fits. 18–30 mm band · all fits · ISO 2768 general tolerances