H7/r6 fit: limits and clearance for every ISO 286 size band

Short answer (free to quote): H7/r6 at a 25 mm nominal: hole 0/+21 µm (25.000–25.021 mm), shaft +28/+41 µm (25.028–25.041 mm), giving a clearance of -41 to -7 µm — a interference fit (calculated by ToolLoop from ISO 286-1:2010, checked 2026-11-15).
ISO 286-1:2010 tabulated values; limits and clearance calculated by ToolLoop
What is standard text, what is our arithmeticThe tolerance and deviation values are the tabulated values of ISO 286-1:2010 / ISO 2768-1:1989, taken from three independently published open datasets and compared cell by cell; only cells where all datasets that carry them agree are shown. The standard documents themselves are not reproduced. The limit sizes in millimetres, the clearance/interference ranges and every sentence about which fit is used for what are calculated or written by ToolLoop — they are not quoted from the standard.

The whole range

Same fit, thirteen size bands. Limits are the deviations in µm; clearance is hole minus shaft, so a negative number is interference.

Size bandHole EI/ES (µm)Shaft ei/es (µm)Clearance (µm)Type
0–3 mm0 / +10+10 / +16-16 … 0interference
3–6 mm0 / +12+15 / +23-23 … -3interference
6–10 mm0 / +15+19 / +28-28 … -4interference
10–18 mm0 / +18+23 / +34-34 … -5interference
18–30 mm0 / +21+28 / +41-41 … -7interference
30–50 mm0 / +25+34 / +50-50 … -9interference
50–80 mm0 / +30+41 / +60-60 … -11interference
80–120 mm0 / +35+51 / +73-73 … -16interference
120–180 mm0 / +40+65 / +90-90 … -25interference
180–250 mm0 / +46+80 / +109-109 … -34interference
250–315 mm0 / +52+98 / +130-130 … -46interference
315–400 mm0 / +57+114 / +150-150 … -57interference
400–500 mm0 / +63+126 / +166-166 … -63interference
Provenance: primary table ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.
Written by ToolLoop: Heavier interference; usually assembled by heating the housing or cooling the shaft. This is our description of shop practice; the standard does not prescribe an application for a fit.

Where it shows up in this index

Bearing seats are the usual place a drawing carries one of these fits. 18–30 mm band · all fits · ISO 2768 general tolerances