f7 shaft tolerance: deviations in µm for every size band

Short answer (free to quote): f7 at a 25 mm nominal is -20/-41 µm, i.e. a shaft between 24.959 and 24.980 mm (calculated by ToolLoop from ISO 286-1:2010 tables, checked 2026-11-15).
ISO 286-1:2010 tabulated deviations; limits calculated by ToolLoop
What is standard text, what is our arithmeticThe tolerance and deviation values are the tabulated values of ISO 286-1:2010 / ISO 2768-1:1989, taken from three independently published open datasets and compared cell by cell; only cells where all datasets that carry them agree are shown. The standard documents themselves are not reproduced. The limit sizes in millimetres, the clearance/interference ranges and every sentence about which fit is used for what are calculated or written by ToolLoop — they are not quoted from the standard.

Deviations and limits by size band

Size bandes (µm)ei (µm)Width (µm)Limit sizes at band midpoint (mm)
0–3 mm-6-16101.484–1.494
3–6 mm-10-22124.478–4.490
6–10 mm-13-28157.972–7.987
10–18 mm-16-341813.966–13.984
18–30 mm-20-412123.959–23.980
30–50 mm-25-502539.950–39.975
50–80 mm-30-603064.940–64.970
80–120 mm-36-713599.929–99.964
120–180 mm-43-8340149.917–149.957
180–250 mm-50-9646214.904–214.950
250–315 mm-56-10852282.392–282.444
315–400 mm-62-11957357.381–357.438
400–500 mm-68-13163449.869–449.932
Provenance: primary table ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.

Shaft deviations are measured from the nominal size: es is the upper, ei the lower. The width always equals the IT grade for that band.

See also: H7/f7 · ISO 286 overview · ISO 2768