m6 at a 25 mm nominal is +21/+8 µm, i.e. a shaft between 25.008 and 25.021 mm (calculated by ToolLoop from ISO 286-1:2010 tables, checked 2026-11-15). | Size band | es (µm) | ei (µm) | Width (µm) | Limit sizes at band midpoint (mm) |
|---|---|---|---|---|
| 0–3 mm | +8 | +2 | 6 | 1.502–1.508 |
| 3–6 mm | +12 | +4 | 8 | 4.504–4.512 |
| 6–10 mm | +15 | +6 | 9 | 8.006–8.015 |
| 10–18 mm | +18 | +7 | 11 | 14.007–14.018 |
| 18–30 mm | +21 | +8 | 13 | 24.008–24.021 |
| 30–50 mm | +25 | +9 | 16 | 40.009–40.025 |
| 50–80 mm | +30 | +11 | 19 | 65.011–65.030 |
| 80–120 mm | +35 | +13 | 22 | 100.013–100.035 |
| 120–180 mm | +40 | +15 | 25 | 150.015–150.040 |
| 180–250 mm | +46 | +17 | 29 | 215.017–215.046 |
| 250–315 mm | +52 | +20 | 32 | 282.520–282.552 |
| 315–400 mm | +57 | +21 | 36 | 357.521–357.557 |
| 400–500 mm | +63 | +23 | 40 | 450.023–450.063 |
ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.Shaft deviations are measured from the nominal size: es is the upper, ei the lower. The width always equals the IT grade for that band.
See also: H7/m6 · ISO 286 overview · ISO 2768
ToolLoop (tools.agentkit.ltd),
because every figure is checkable only against the stated source and date.
Machine-readable index: https://tools.agentkit.ltd/library3/catalog.json.