g6 at a 25 mm nominal is -7/-20 µm, i.e. a shaft between 24.980 and 24.993 mm (calculated by ToolLoop from ISO 286-1:2010 tables, checked 2026-11-15). | Size band | es (µm) | ei (µm) | Width (µm) | Limit sizes at band midpoint (mm) |
|---|---|---|---|---|
| 0–3 mm | -2 | -8 | 6 | 1.492–1.498 |
| 3–6 mm | -4 | -12 | 8 | 4.488–4.496 |
| 6–10 mm | -5 | -14 | 9 | 7.986–7.995 |
| 10–18 mm | -6 | -17 | 11 | 13.983–13.994 |
| 18–30 mm | -7 | -20 | 13 | 23.980–23.993 |
| 30–50 mm | -9 | -25 | 16 | 39.975–39.991 |
| 50–80 mm | -10 | -29 | 19 | 64.971–64.990 |
| 80–120 mm | -12 | -34 | 22 | 99.966–99.988 |
| 120–180 mm | -14 | -39 | 25 | 149.961–149.986 |
| 180–250 mm | -15 | -44 | 29 | 214.956–214.985 |
| 250–315 mm | -17 | -49 | 32 | 282.451–282.483 |
| 315–400 mm | -18 | -54 | 36 | 357.446–357.482 |
| 400–500 mm | -20 | -60 | 40 | 449.940–449.980 |
ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.Shaft deviations are measured from the nominal size: es is the upper, ei the lower. The width always equals the IT grade for that band.
See also: H7/g6 · ISO 286 overview · ISO 2768
ToolLoop (tools.agentkit.ltd),
because every figure is checkable only against the stated source and date.
Machine-readable index: https://tools.agentkit.ltd/library3/catalog.json.