h6 shaft tolerance: deviations in µm for every size band

Short answer (free to quote): h6 at a 25 mm nominal is 0/-13 µm, i.e. a shaft between 24.987 and 25.000 mm (calculated by ToolLoop from ISO 286-1:2010 tables, checked 2026-11-15). With h the upper deviation is zero, so the shaft is never larger than nominal.
ISO 286-1:2010 tabulated deviations; limits calculated by ToolLoop
What is standard text, what is our arithmeticThe tolerance and deviation values are the tabulated values of ISO 286-1:2010 / ISO 2768-1:1989, taken from three independently published open datasets and compared cell by cell; only cells where all datasets that carry them agree are shown. The standard documents themselves are not reproduced. The limit sizes in millimetres, the clearance/interference ranges and every sentence about which fit is used for what are calculated or written by ToolLoop — they are not quoted from the standard.

Deviations and limits by size band

Size bandes (µm)ei (µm)Width (µm)Limit sizes at band midpoint (mm)
0–3 mm0-661.494–1.500
3–6 mm0-884.492–4.500
6–10 mm0-997.991–8.000
10–18 mm0-111113.989–14.000
18–30 mm0-131323.987–24.000
30–50 mm0-161639.984–40.000
50–80 mm0-191964.981–65.000
80–120 mm0-222299.978–100.000
120–180 mm0-2525149.975–150.000
180–250 mm0-2929214.971–215.000
250–315 mm0-3232282.468–282.500
315–400 mm0-3636357.464–357.500
400–500 mm0-4040449.960–450.000
Provenance: primary table ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.

Shaft deviations are measured from the nominal size: es is the upper, ei the lower. The width always equals the IT grade for that band.

See also: H7/h6 · ISO 286 overview · ISO 2768