js6 shaft tolerance: deviations in µm for every size band

Short answer (free to quote): js6 at a 25 mm nominal is +6.5/-6.5 µm, i.e. a shaft between 24.994 and 25.006 mm (calculated by ToolLoop from ISO 286-1:2010 tables, checked 2026-11-15). With js the zone is symmetric about nominal, so the shaft can come out either side.
ISO 286-1:2010 tabulated deviations; limits calculated by ToolLoop
What is standard text, what is our arithmeticThe tolerance and deviation values are the tabulated values of ISO 286-1:2010 / ISO 2768-1:1989, taken from three independently published open datasets and compared cell by cell; only cells where all datasets that carry them agree are shown. The standard documents themselves are not reproduced. The limit sizes in millimetres, the clearance/interference ranges and every sentence about which fit is used for what are calculated or written by ToolLoop — they are not quoted from the standard.

Deviations and limits by size band

Size bandes (µm)ei (µm)Width (µm)Limit sizes at band midpoint (mm)
0–3 mm+3-36.01.497–1.503
3–6 mm+4-48.04.496–4.504
6–10 mm+4.5-4.59.07.995–8.005
10–18 mm+5.5-5.511.013.995–14.005
18–30 mm+6.5-6.513.023.994–24.006
30–50 mm+8-816.039.992–40.008
50–80 mm+9.5-9.519.064.990–65.010
80–120 mm+11-1122.099.989–100.011
120–180 mm+12.5-12.525.0149.988–150.012
180–250 mm+14.5-14.529.0214.986–215.014
250–315 mm+16-1632.0282.484–282.516
315–400 mm+18-1836.0357.482–357.518
400–500 mm+20-2040.0449.980–450.020
Provenance: primary table ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.

Shaft deviations are measured from the nominal size: es is the upper, ei the lower. The width always equals the IT grade for that band.

See also: H7/js6 · ISO 286 overview · ISO 2768