k6 at a 25 mm nominal is +15/+2 µm, i.e. a shaft between 25.002 and 25.015 mm (calculated by ToolLoop from ISO 286-1:2010 tables, checked 2026-11-15). | Size band | es (µm) | ei (µm) | Width (µm) | Limit sizes at band midpoint (mm) |
|---|---|---|---|---|
| 0–3 mm | +6 | 0 | 6 | 1.500–1.506 |
| 3–6 mm | +9 | +1 | 8 | 4.501–4.509 |
| 6–10 mm | +10 | +1 | 9 | 8.001–8.010 |
| 10–18 mm | +12 | +1 | 11 | 14.001–14.012 |
| 18–30 mm | +15 | +2 | 13 | 24.002–24.015 |
| 30–50 mm | +18 | +2 | 16 | 40.002–40.018 |
| 50–80 mm | +21 | +2 | 19 | 65.002–65.021 |
| 80–120 mm | +25 | +3 | 22 | 100.003–100.025 |
| 120–180 mm | +28 | +3 | 25 | 150.003–150.028 |
| 180–250 mm | +33 | +4 | 29 | 215.004–215.033 |
| 250–315 mm | +36 | +4 | 32 | 282.504–282.536 |
| 315–400 mm | +40 | +4 | 36 | 357.504–357.540 |
| 400–500 mm | +45 | +5 | 40 | 450.005–450.045 |
ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.Shaft deviations are measured from the nominal size: es is the upper, ei the lower. The width always equals the IT grade for that band.
See also: H7/k6 · ISO 286 overview · ISO 2768
ToolLoop (tools.agentkit.ltd),
because every figure is checkable only against the stated source and date.
Machine-readable index: https://tools.agentkit.ltd/library3/catalog.json.