r6 shaft tolerance: deviations in µm for every size band

Short answer (free to quote): r6 at a 25 mm nominal is +41/+28 µm, i.e. a shaft between 25.028 and 25.041 mm (calculated by ToolLoop from ISO 286-1:2010 tables, checked 2026-11-15).
ISO 286-1:2010 tabulated deviations; limits calculated by ToolLoop
What is standard text, what is our arithmeticThe tolerance and deviation values are the tabulated values of ISO 286-1:2010 / ISO 2768-1:1989, taken from three independently published open datasets and compared cell by cell; only cells where all datasets that carry them agree are shown. The standard documents themselves are not reproduced. The limit sizes in millimetres, the clearance/interference ranges and every sentence about which fit is used for what are calculated or written by ToolLoop — they are not quoted from the standard.

Deviations and limits by size band

Size bandes (µm)ei (µm)Width (µm)Limit sizes at band midpoint (mm)
0–3 mm+16+1061.510–1.516
3–6 mm+23+1584.515–4.523
6–10 mm+28+1998.019–8.028
10–18 mm+34+231114.023–14.034
18–30 mm+41+281324.028–24.041
30–50 mm+50+341640.034–40.050
50–80 mm+60+411965.041–65.060
80–120 mm+73+5122100.051–100.073
120–180 mm+90+6525150.065–150.090
180–250 mm+109+8029215.080–215.109
250–315 mm+130+9832282.598–282.630
315–400 mm+150+11436357.614–357.650
400–500 mm+166+12640450.126–450.166
Provenance: primary table ottonic/standards-mcp-server (src/domain/iso286.ts, MIT); cross-checked against clay-good/anvilate (tolerance/data/iso286_*.yaml, MIT) and chenzefeng09/iso-286-fits (fits.json, MIT). 393 overlapping cells compared, 0 disagreements, checked 2026-11-15.

Shaft deviations are measured from the nominal size: es is the upper, ei the lower. The width always equals the IT grade for that band.

See also: H7/r6 · ISO 286 overview · ISO 2768